See what is happening on every line, as it happens. We design, build and modernise HMI and SCADA systems that give operators clear control and give managers live data they can trust.
SCADA is often the oldest software in the plant. It keeps running, so it gets left alone, until it stops the plant from moving forward.

New systems designed around your process, for desktop, web and mobile.

Clear, consistent screens based on high-performance HMI principles (ISA-101), so abnormal situations stand out.

Rationalised, prioritised alarms following ISA-18.2 practice, with notifications to the right people by email, SMS or voice call.

Reliable time-series history for trends, investigations and compliance, using the Ignition historian or Canary.

Automatic shift, production and energy reports, plus dashboards for every level.

Siemens, Rockwell (Allen-Bradley), Modbus and OPC UA devices brought into one system.

High-availability architecture, role-based access and secure remote access.

PLC changes and troubleshooting for Siemens and Rockwell systems as part of your SCADA project.
Older SCADA platforms get harder to maintain, expand and connect to MES or analytics. We help you move to Ignition in planned stages, keeping what works and improving what doesn’t. A migration is also the right moment to fix alarm floods, clean up tag names and make screens usable on any device.
We audit your architecture, screens, tags, scripts and dependencies.
We agree the migration plan, risks, cut over strategy and rollback options.
We migrate tags, alarms, historical data and databases.
Screens are redesigned for web and mobile, not just copied across.
Parallel running and phased switchover, scheduled around production.
A hypercare period after go-live, training for your team and ongoing support.
A modern SCADA gives your plant live visibility, the “See” step of the journey. Once that data is reliable, it can feed MES for production execution and analytics for continuous improvement.
An HMI (human-machine interface) is the screen an operator uses to monitor and control a machine or process. SCADA (supervisory control and data acquisition) connects many machines and HMIs across a plant or site, and adds alarms, history, reporting and central control.
Usually, yes. We connect to Siemens, Rockwell (Allen-Bradley), Modbus and OPC UA devices, and many others, without replacing your control hardware.
It depends on the size of the system. A single area can take a few weeks; a plant-wide migration is usually phased over several months. The assessment gives you a realistic timeline.
In most cases, yes. We run the new system alongside the old one, switch over in phases during planned windows, and agree a rollback plan in advance, so disruption is kept to a minimum.
Ignition is web-based, runs on standard IT servers and is licensed by server rather than by screen or tag, which makes it practical to grow. It also connects easily to databases, MES and cloud platforms. We recommend it when it fits your needs, and we’ll tell you if it doesn’t.
Ignition is web-based, runs on standard IT servers and is licensed by server rather than by screen or tag, which makes it practical to grow. It also connects easily to databases, MES and cloud platforms. We recommend it when it fits your needs, and we’ll tell you if it doesn’t.
Tell us what you want to improve. Our free assessment will point you to the right starting point.